| − | In this work they have noticed that magnetic field created by ac line disrupts their experiments. | + | In this work they have noticed that magnetic field created by ac line disrupts their experiments, by applying a magnetic field with an opposite phase they reduce the noise to 1 nT. As a magnetometer they achieved 12 pT/sqrt(Hz) with spatial resolution 100 um^2. |
| + | |||
| + | For the coils they use low ripple current source <2uA (Newport 505), they insert permalloy plates into the room walls. | ||
Revision as of 16:40, 28 December 2019
BEC
Spin-echo-based magnetometry with spinor Bose-Einstein condensates
In this work they have noticed that magnetic field created by ac line disrupts their experiments, by applying a magnetic field with an opposite phase they reduce the noise to 1 nT. As a magnetometer they achieved 12 pT/sqrt(Hz) with spatial resolution 100 um^2.
For the coils they use low ripple current source <2uA (Newport 505), they insert permalloy plates into the room walls.