Magnetometry
Revision as of 17:29, 28 December 2019 by Kot (talk | contribs) (→Spin-echo-based magnetometry with spinor Bose-Einstein condensates)
BEC
Spin-echo-based magnetometry with spinor Bose-Einstein condensates
Abstract. In this work they have noticed that magnetic field created by ac line disrupts their experiments, by applying a magnetic field with an opposite phase they reduce the noise to 1 nT. As a magnetometer they achieved 12 pT/sqrt(Hz) with spatial resolution 100 um^2.
Technicalities. For the coils they use low ripple current source <2uA (Newport 505), they insert permalloy plates into the room walls. The BEC of 87Rb is prepared in a crossed far-off resonant optical trap (FORT with waxial=30 Hz, wrad=100 Hz), 5*103 atoms are prepared in F=2.
Idea. The rf Hahn-echo pulse sequence is sent:
If there is an external varying magnetic field the phase measured in this experiment is: