Spin-echo-based magnetometry with spinor Bose-Einstein condensates

Abstract. In this work they have noticed that magnetic field created by ac line disrupts their experiments, by applying a magnetic field with an opposite phase they reduce the noise to 1 nT. As a magnetometer they achieved 12 pT/sqrt(Hz) with spatial resolution 100 um^2.

Technicalities. For the coils they use low ripple current source <2uA (Newport 505), they insert permalloy plates into the room walls. The BEC of 87Rb is prepared in a crossed far-off resonant optical trap (FORT with waxial=30 Hz, wrad=100 Hz), 5*103 atoms are prepared in F=2.

Idea. The rf Hahn-echo pulse sequence is sent: \pi/2\rightarrow\pi\rightarrow\pi/2 If there is an external varying magnetic field the phase measured in this experiment is: \theta = \frac{g_F \mu_B}{\hbar} \left[ \int_0^{\tau/2}b(t)dt- \int_{\tau/2}^{\tau}b(t)dt \right]